4P/AC/SPD_385V/AC, ProSurge, Surge Protective Device (SPD)

299,000.00 MMK 299000.0 MMK 299,000.00 MMK

299,000.00 MMK

  • Mounting Type
  • Degree of protection (IP)
  • Enclosure Material
  • Protection Mode
  • Max. continuous operating voltage (AC), Uc, L-N
  • Max. continuous operating voltage (AC), Uc, N-PE
  • Norminal discharge current (8/20) In
  • Max. dischrage current (8/20), Imax
  • Lightning impulse current (10/350) Limp, L-N
  • Lightning impulse current (10/350) Limp, N-PE
  • Voltage protection level Up, L-N
  • Voltage protection level Up, N-PE
  • Response time, tA, L-N
  • Response time, tA, N-PE
  • Temporary overvoltage TOV withstand mode, L-N
  • Temporary overvoltage TOV withstand mode, N-PE
  • Flow current & interrupt rating Ifi, N-PE
  • Leakage current, Ipe
  • Short-circuit current rating, Isscr
  • Backup fuse (only required if not already provide in mains)
  • Operating temperature range
  • Altitude
  • Cross-section of connection wire (max)
  • Installation width
  • Thermal disconnector
  • Remote alarm contact
  • Approvals, Certifications
  • Switching capability Un/In
  • Cross-section of remote signaling wire (max)

This combination does not exist.

Mounting Type: 35mm DIN-rail in accordance with EN 50022/DIN46277-3
Degree of protection (IP): IP20
Enclosure Material: Thermoplastic; extinguishing degree UL94 V-0
Protection Mode: L-N, N-PE
Max. continuous operating voltage (AC), Uc, L-N: 385V
Max. continuous operating voltage (AC), Uc, N-PE: 255V
Norminal discharge current (8/20) In: 20kA
Max. dischrage current (8/20), Imax: 50kA
Lightning impulse current (10/350) Limp, L-N: 7.5kA
Lightning impulse current (10/350) Limp, N-PE: 12.5kA
Voltage protection level Up, L-N: 1.8kV
Voltage protection level Up, N-PE: 1.5kV
Response time, tA, L-N: ≤25ns
Response time, tA, N-PE: ≤100ns
Temporary overvoltage TOV withstand mode, L-N: 403V/5s
Temporary overvoltage TOV withstand mode, N-PE: 1200V/200ms
Flow current & interrupt rating Ifi, N-PE: 100A
Leakage current, Ipe: <0.1mA
Short-circuit current rating, Isscr: 25kArms
Backup fuse (only required if not already provide in mains): ≤125A gL/gG
Operating temperature range: -40°C~+85°C
Altitude: -500m~+4000m
Cross-section of connection wire (max): Single-strand 35mm^2; multi-strand 25mm^2
Installation width: 4 module, DIN 43880
Thermal disconnector: Internal Green-Normal; red-failure
Remote alarm contact: Optional
Approvals, Certifications: TUV,CE
Switching capability Un/In: AC: 250V/0.5A, DC:250V/0.1A; 125V/0.2A; 75V/0.5A
Cross-section of remote signaling wire (max): 1.5mm^2 (or # 16AWG)

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

DT50/385-(3V+T)-S (Surge Protection Device(SPD))

  • TUV certified T1+ T2 SPD per IEC/EN 61643-11 standard.
  • Prewired two poles SPD (“3+1” circuit) for use in three phase TN/TT systems
  • Unique thermal disconnector design provides quick thermal response and secure disconnection
  • Lightning current capacity up to 7.5kA 10/350μs (L-N), 12.5kA 10/350μs (N-PE)
  • Surge current capability up to 50kA 8/20μs
  • Low voltage protection level
  • High short-circuit current rating up to 25kArms, suitable for application in most AC power system.
  • Degradation failure indication and optional remote signal contact.
  • Pluggable module for easy replacement without the need to remove system wiring.
  • Wide operating temperature -40'C ~85'C
  • 35mm DIN-rail mounting
  • Comply with UL1449 5th Edition, IEEE C62.41, CSA C22.2 standards