3P/PV/SPD_1000V/DC, ProSurge, Surge Protective Device (SPD)

273,000.00 MMK 273000.0 MMK 273,000.00 MMK

273,000.00 MMK

  • Mounting Type
  • Degree of protection (IP)
  • Enclosure Material
  • Protection Mode
  • Max. dischrage current (8/20), Imax
  • Leakage current, Ipe
  • Operating temperature range
  • Altitude
  • Cross-section of connection wire (max)
  • Installation width
  • Thermal disconnector
  • Remote alarm contact
  • Approvals, Certifications
  • Remote alarm contact type
  • Switching capability Un/In
  • Cross-section of remote signaling wire (max)
  • Nominal Voltage (DC), Un
  • Max. continuous operating voltage (DC), Ucpv
  • Nominal discharge current (8/20), In
  • Lightning impulse current (10/350), Iimp
  • Voltage protection level Up, DC+/- to PE
  • Voltage protection level Up, DC+ to DC-
  • Response time, tA
  • Short-circuit Current, Iscpv

This combination does not exist.

Mounting Type: 35mm DIN-rail in accordance with EN 50022/DIN46277-3
Degree of protection (IP): IP20
Enclosure Material: Thermoplastic; extinguishing degree UL94 V-0
Protection Mode: DC+ to DC-, DC+/- to PE
Max. dischrage current (8/20), Imax: 50kA
Leakage current, Ipe: <0.1mA
Operating temperature range: -40°C~+85°C
Altitude: -500m~+4000m
Cross-section of connection wire (max): Single-strand 35mm^2; multi-strand 25mm^2
Installation width: 3 modules, DIN 43880
Thermal disconnector: Internal Green-Normal; red-failure
Remote alarm contact: Optional
Approvals, Certifications: TUV,CE
Remote alarm contact type: Isolated Form C
Switching capability Un/In: AC: 250V/0.5A, DC:250V/0.1A; 125V/0.2A; 75V/0.5A
Cross-section of remote signaling wire (max): Max.1.5mm^2 (or # 16AWG)
Nominal Voltage (DC), Un: 1000V
Max. continuous operating voltage (DC), Ucpv: 1120V
Nominal discharge current (8/20), In: 20kA
Lightning impulse current (10/350), Iimp: 6kA
Voltage protection level Up, DC+/- to PE: 3.5kV
Voltage protection level Up, DC+ to DC-: 3.5kV
Response time, tA: ≤25ns
Short-circuit Current, Iscpv: 1000A

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

PV50/1000-V-CD-S

  • TUV certified T1+ T2 DC SPD per IEC/EN 61643-31 standard.
  • 18mm narrow model design, prewired three poles of Y circuit for common mode & different mode protection
  • Application in Photovoltaic (PV) systems and other DC power system like charging system for electric vehicles etc.
  • Unique thermal disconnector design
  • Lightning current capacity up to 7.5kA 10/350μs
  • Surge current capability up to 50kA 8/20μs
  • Low voltage protection level
  • Degradation failure indication and optional remote signal contact.
  • Pluggable module for easy replacement without the need to remove system wiring.
  • Wide operating temperature -40'C ~85'C
  • 35mm DIN-rail mounting